Accurate Security & Lock

A Plant Door That Opens on a Pull and a Push

The frames below run from the door opened up to take the new case, through the case being fitted, to both paddles on and the door back in service.

  • Stile of a plant door with the lock cut-out opened and a bore through the face
    During the fit

    The door opened up. On an opening like this the hardware is the only thing between a controlled entrance and one that does not close.

  • Close view of the mortise pocket and bore in the door edge as the lock case goes in
    During the fit

    Cutting for the case. Precision here is what stops the latch rubbing and the door being left unlatched.

  • Lock case secured in the door stile with its latch bolt and deadlatch showing
    During the fit

    The case secured. The latch and deadlatch are checked against the strike rather than assumed to line up.

  • Two paddle assemblies on opposite faces of the same door, one black and one brushed metal
    Back in service

    A paddle on each side. Staff push out; the same door pulls open from the other face, and neither action needs a free hand.

  • The completed door viewed through glass, with the pull handle and paddle on the stile
    Back in service

    In service. The door latches when it shuts and opens on one movement from either side, which is the state a plant entrance has to hold to.

1 of 5

The door at Woodstock Sterile Solutions had a worn lock case and slack paddles on both faces. We replaced the case and both paddles and set the latch against the strike, so the door now opens on one movement from either side and latches when it swings shut.

A door that a shift passes through all day has to do two different jobs at once. From the inside it has to let people out immediately, without a handle to grip or a key to find. From the outside it has to give a controlled way in, and it has to shut properly behind whoever used it last.

Paddle hardware does both, because the paddle is a large flat target rather than a small turning one. But the paddle is only a lever bolted to a lock case inside the door, and once that case is worn the door stops meeting its strike - which turns a hardware complaint into an opening that is not reliably closed.

One door, two directions

Inside, the push paddle is the whole operating surface. Somebody carrying a tray or a carton leans on it and the door is open, which is exactly what an exit wants to be.

Outside, the same assembly works in the opposite direction: a straight pull rather than a turn. Both movements are worth having on a plant door, because the alternative - a lever - breaks under exactly the handling this door gets.

Why a failing latch becomes a security problem

When the case wears, the latch stops reaching the strike cleanly. The door then looks shut and is not, and the person closing it will not notice - they swung it, it made a sound, they walked away.

That is the failure mode worth naming. On a plant entrance, an opening that latches most of the time is the one nobody reports, because it only fails in a way you cannot see from the inside of a car park.

  • Push paddle inside: egress in one movement, with no handle to find.
  • Pull paddle outside: the same assembly working in the opposite direction.
  • A replaced lock case, so the latch reaches the strike every time.
  • The latch and deadlatch set against the strike, checked with the door shut.

Replacing the case and both paddles

The case comes out of the door, not off the surface of it, so the leaf is opened up to take the new one: face bored, edge pocketed, fixings cut square. Then the case goes in and the latch and deadlatch are set against the strike before either paddle goes on.

Both paddles were replaced because both were part of the same worn assembly. Doing one face and not the other leaves an opening that behaves differently depending on which side you are standing on, which is how a door teaches people to misuse it.

The premises and the account

The job was at Woodstock Sterile Solutions, 2210 Lake Shore Dr, Woodstock, IL 60098, and it is a commercial account rather than a one-off call-out.

That matters for how the hardware is chosen. A plant entrance is judged on whether it works on the night shift in February, not on how it feels on the day it is fitted, and the accountability is different too - an opening that does not close reliably is a security finding, not an inconvenience to be lived with.

Ready to get it sorted?

Call either line and speak to one of our own technicians. We cover Northern Illinois and Southern Wisconsin, and we attend lockouts and failed door hardware around the clock.

Office hours:
Monday to Saturday, 8:30am - 5:00pm · Closed Sunday
Emergencies:
24-hour emergency call-out

Illinois licence 191.000502 · Licensed, bonded and insured

Call either line

Both numbers reach our own technicians. Lockouts and failed door hardware are attended at any hour, including Sundays and holidays.

Call (847) 854-9077