A Shop Door That Would Not Stay Shut in Lake Geneva

The frames below run from the entrance as it was, through the head being stripped and the new shoe mounted, to the closer fitted and the door closing under control.

  • Glass entrance door head with the previous closer removed and exposed fixing points on the frame
    During the fit

    The old closer came off first. Nothing new goes on until the head is sound, because a closer that works loose is worse than one that was never fitted.

  • Looking out from inside the shop through the entrance towards the car park and a delivery truck
    Before the work

    Standing at the entrance looking out. This is the exposure: open frontage, open tarmac, and nothing between the door and the weather.

  • Closer bracket fixed to the door head, with suspended ceiling and a smoke detector visible above
    During the fit

    The bracket at the head. It carries the whole closing force, so it is the part that has to be right.

  • Heavy duty closer and arm on the glass shop door, with brickwork reflected in the glazing
    Closing under control

    The closer in place. The door closes itself and latches again, which is the state a shopfront has to be in at the end of the day.

  • Door closer arm across the head of the glass entrance with its linkage at the frame
    Closing under control

    Finished at the head. A door that closes under control is also a door that is not standing open while the shop trades.

1 of 5

The glass shopfront door at Jersey Mike's in Lake Geneva would not close on windy days, so the premises traded with an opening it could not shut. We fitted a heavy duty closer and arm, mounted on sound fixings, and set it so the door closes and latches without being pulled.

A shop door that will not close is easy to describe as an inconvenience and hard to live with as a building. It means the frontage is open when the weather is against it, the air conditioning is fighting the car park, and closing up depends on somebody pulling the door hard enough at the right angle.

This one had a closer on it already, which is why it read as a small fault rather than a missing part. But a closer that cannot move the leaf it is attached to is not doing anything, and no amount of adjustment recovers force it does not have.

The door that would not stay closed

On a calm day nothing was wrong. Once the wind got on the frontage the door would stop short of the frame, or sit open and let the draught finish the job - and the fault only existed on the days it mattered.

That pattern tends to produce workarounds rather than repairs. Something gets wedged against the door, or staff learn to pull it, and the fault stops being reported while the opening stays unclosed.

Why wind beats an under-specified closer

A closer has to overcome the weight of the leaf, the friction of the hinges or pivots, the latch, and any pressure on the door face. On an exposed frontage the last of those is not small, and it pushes exactly when the door is trying to close.

An under-sized closer runs out of closing force before the latch arrives, and adjusting it only changes how fast it fails. The honest fix is a closer rated for the leaf and the exposure, on mounting that can carry the load.

  • A door left standing open, or wedged, through the trading day.
  • A frontage that cannot be relied on to shut at closing time.
  • An old closer working loose because its fixings were not carrying it.
  • The same leaf asked to do two jobs - keep the weather out and let people through - with hardware sized for neither.

What was fitted and why it holds

A heavy duty overhead closer with a matching arm, on a mounting shoe fixed into the head where the frame can actually take it. The old fixings came off first, because a closer bolted to metal that has already been drilled and re-drilled is a closer that will work loose.

Then it was set: sweep for the travel, latch for the last few centimetres, adjusted with the door closing under its own power rather than held open. The test is behavioural - the door shuts itself, meets the strike and stays shut.

The premises and the account

The job was at Jersey Mike's Subs, 88 E Geneva Square, Lake Geneva, WI 53147, and it is a commercial account rather than a one-off call-out.

It is also the second visit to this premises: the back service door was given a panic bar with keyed outside access on an earlier job. That is what an account looks like in practice - the same building, a different opening, and the faults that actually show up in daily use rather than the ones a general survey would guess at.

Ready to get it sorted?

Call either line and speak to one of our own technicians. We cover Northern Illinois and Southern Wisconsin, and we attend lockouts and failed door hardware around the clock.

Office hours:
Monday to Saturday, 8:30am - 5:00pm · Closed Sunday
Emergencies:
24-hour emergency call-out

Illinois licence 191.000502 · Licensed, bonded and insured

Call either line

Both numbers reach our own technicians. Lockouts and failed door hardware are attended at any hour, including Sundays and holidays.

Call (847) 854-9077